Bolted-joint analyzer

Check bolt load, residual clamp, separation, and slip.

Static screening only. Joint geometry, fatigue, tightening variation, and applicable specifications require separate checks.

%

Options

Starting values are examples. Replace them with your measurements.

Result

Enter your values, then calculate.

Calculation method

C = kb/(kb+kj). Maximum bolt load uses maximum preload; residual clamp uses minimum preload. After separation the bolt carries the external load.

Method 2026-10-05.1. Independent review pending.

Understanding preload and joint separation

In a clamped joint, an external tensile load both increases bolt tension and reduces compression in the joined parts. The relative stiffness of the bolt and joint determines that split in the linear model. It is not correct to add the entire external load to preload while also assuming the clamping force stays unchanged.

Enter stiffness and preload consistently

Bolt and joint stiffness must describe the same load path and use compatible units. Check both minimum and maximum preload: the lower value can control separation or slip, while the higher value can control bolt stress. Friction is an input assumption, not a measured property of the assembly.

Separation changes the model

The stiffness split applies while the joint remains clamped. Once compression is lost, the load path changes. Eccentric loads, gasket behavior, relaxation, temperature changes, and fatigue require more detailed treatment. A separation or slip warning identifies a limit of the proposed joint, not an installation instruction.

Following the stiffness fraction

If bolt stiffness is one quarter of the combined bolt-and-joint stiffness, the linear model initially assigns one quarter of an added axial load to increased bolt tension. The remaining portion reduces compression in the clamped members. For an additional 1,000 N, that means 250 N added to the bolt and 750 N removed from joint compression before separation.

This load split depends on the stiffness values describing the same physical joint. A gasket, short grip, thick washer, or flexible member can change the effective response. Do not use a stiffness from another assembly merely because its bolt diameter matches. Evaluate the low-preload condition when checking whether compression remains, and the high-preload condition when checking maximum bolt load. Frictional resistance depends on the clamping force and the coefficient selected for the interfaces; it is not interchangeable with bolt shear strength. If the joint is predicted to separate, the pre-separation linear split should not be extended as though the original contact condition still exists.

Formula

C = kb/(kb+kj). Maximum bolt load uses maximum preload; residual clamp uses minimum preload. After separation the bolt carries the external load.

Embed this calculator

Paste this HTML into a page that accepts iframes. The widget uses the same calculation method and keeps its warnings visible. No account is needed.

Adjust the height to suit your page. Saved work is not available inside the widget. Preview addresses are temporary; use the permanent site address for a published embed.